REFURBISHED

Buy Karl Storz Telecam

From 3,53,000*

background

202320-20, KARL STORZ TELECAM DX PAL CCU & C-Mount Camera Head From ₹3,53,000*

Need Help Choosing the Correct Configuration Get in Touch with a Technical Expert



Technical Specification

1-CCD Chip Standard Resolution Progressive Scan AWB & Digital Image Processing Automatic Exposure Control Optical Parfocal Lens, Integrated


Applications

Laparoscopic General Surgery Laparoscopic Gynaecology Endo-Gynaecology Endo-Urology Endoscopic ENT


Condition

Refurbished Grade A1  (Like New, Scratch-less, 100% Perfect Working Condition)


Warranty

Standard 12 Months Limited Liability Manufacturer's Warranty From Date of Installation Not Covered Under Standard Warranty Probes/Consumables/Cables/Accessories/ Accidental Damage/Electronic Damage due to Voltage Fluctuation & Due to Non Compliance of Pre-Requisites and Optimal Instructions for Use.


Karl Storz Telecam is the Steadfast 1-CCD Backbone of Entry-level Laparoscopy. A Reliable Solution, It Features Best in Class Portability, Connectivity Options, Cost-effectiveness, and Commendable Visual Capabilities, Redefining Accessibility in Laparoscopic Imaging.


What is a 1-Chip Camera System? A 1-chip camera system, Such as the Karl Storz Telecam Laparoscopic Camera, integrates advanced imaging technology into a compact and efficient design. With its single CCD sensor, the Telecam system offers Good image quality and clarity, providing surgeons with Decent Visualization during Laparoscopic procedures.

Resolution of the Karl Storz Telecam Camera: The Telecam Camera has a Standard PAL resolution, known as SD-PAL, with a More clear and detailed imaging during laparoscopic procedures compared to other 1-Chip Single Chip Camera Alternatives.

The Karl Storz Telecam Camera is ideal for:

  • Entry-level surgeons seeking reliable imaging technology to support their practice.
  • PG surgeons transitioning into independent practice, benefiting from its user-friendly design and high-quality imaging.
  • On-call surgeons in need of a dependable standby camera, offering peace of mind with consistent performance and ease of use.

Recommended Accessories: To enhance the functionality of the Telecam Camera system, we recommend using compatible accessories such as:

These accessories ensure seamless integration and optimal performance during surgical procedures.

A Laparoscopy Endovision Setup, Karl Storz Telecam Laparoscopy camera, with Karl Storz 300w xenon light source & Karl Storz 24" HD Wideview Monitor.

Versatile Compatibility with Surgical Displays as well at TV's:

The Karl Storz Telecam Laparoscopic Camera offers versatile connectivity options, allowing it to be connected to a variety of surgical displays.

  1. S-Video connectivity to Connect the Telecam Camera to Medical-Grade Monitors, ensuring high-quality imaging for precise visualization during surgery.
  2. For compatibility with CRT TVs, the Telecam Camera supports composite connections, enabling seamless integration with older display systems without sacrificing image clarity.
  3. Connect the Telecam Camera to standard HDTVs using composite cables, providing flexibility in display options and ensuring compatibility with modern surgical setups.

Maintenance and Reprocessing Guidelines for Karl Storz Telecam Camera

To ensure the longevity and optimal performance of the Karl Storz Telecam Camera , adhere to the following maintenance and reprocessing guidelines:

  • Storage Conditions: Store the equipment in a safe, dry place with a controlled temperature maintained between 19-27°C to prevent damage from moisture or extreme temperatures.
  • Sterilization Procedures: All items and instrumentation should be sterilized according to their prescribed methods to maintain sterility and prevent contamination during surgical procedures.
  • Electrical System Requirements: Ensure that the operating room has electrical systems installed in compliance with applicable national regulations, providing uninterrupted regulated 230V/50 Hz AC power supply to the equipment.
  • Grounding Standards: Verify that grounding (earth leakage) is maintained below 2 volts to prevent electrical hazards and potential damage to the equipment. Improper grounding can pose risks to both patients and surgical staff.
  • Power Cable Compatibility: The equipment is designed to be used with standard 3-pin power cables, ensuring compatibility and safety during operation.
  • Regular Inspection: Conduct regular inspections of the Telecam Camera head for signs of wear, damage, or malfunction. Replace any worn components or parts as necessary to maintain optimal performance.
  • Cleaning Protocols: Follow manufacturer-recommended cleaning protocols to remove debris and contaminants from the camera head, ensuring clear and consistent imaging quality.
  • Preventive Maintenance: Implement a preventive maintenance schedule to perform routine checks and servicing of the equipment. This helps identify potential issues early and prevents unexpected downtime during surgical procedures.
  • Technical Support: In case of any technical issues or concerns, contact Karl Storz technical support for assistance and troubleshooting guidance. Our team is dedicated to ensuring the reliable operation of your Telecam Camera system.

M-Advantage Service Support

Do You Already Have an Existing Karl Storz Telecam System That's Not Working? Why Buy, When We Can Get it Serviced.

Talk to Our Service Team >